									Possible Causes | Remedy | 
						
							| Generator not charging when running at about 20 m.p.h. with no lights in use. Due to:- |  | 
						
							| Broken or loose connection in generator circuit, or regulator not functioning correctly. | Examine charging and field circuit wiring. Tighten loose connection or renew broken lead. Particularly, examine battery connections. Examine regulator. | 
						
							| Commutator greasy or dirty. 
 | Clean with soft rag moistened in petrol. | 
						
							| Giving low or intermittent output, when car is running steadily in top gear. Due to:-- 
 
 |  | 
						
							| Generator belt slipping. 
 | Adjust belt (see Section B). | 
						
							| Loose or broken connections In generator circuit, | Examine charging and field circuits wiring. Tighten loose connections or replace broken lead. Particularly examine battery connections. | 
						
							| Brushes greasy or dirty. | Clean with soft rag moistened in petrol. | 
						
							| Brushes worn or not fitted correctly. | Renew worn brushes. See that brushes bed  correctly. | 
						
							| Regulator not functioning correctly. | Examine regulator. | 
						
							|  |  | 
						
							| Giving high output, Due to:- 
 
 
 |  | 
						
							| Regulator not functioning correctly. 
 
 
 
 | Examine regulator. |